1Administrative Researcher, Faculty of Engineering, Cooperative University of Colombia, Medellin, Antioquia, Colombia., Colombia
2Professor, Faculty of Architecture and Engineering, Civil Construction, Institución Universitaria Colegio , Colombia
3Mayor de Antioquia, Medellín, Colombia, Colombia
4 Faculty of Engineering, Universidad Cooperativa de Colombia, Street 50A No 41-61, Medellín, Antioquia, Colombia, 86002., Colombia
BibTex Citation Data :
@article{IJRED62461, author = {Olga Morales and Nicolas Pardo and Juan Gonzalez}, title = {Carbon footprint assessment for university campuses using corporate accounting and reporting standard protocol: Cross-campus analysis in hot–dry and hot–humid climates}, journal = {International Journal of Renewable Energy Development}, volume = {0}, number = {0}, year = {2027}, keywords = {Carbon footprint, Cold climate, Emissions, Greenhouse gas, Higher education institutions}, abstract = { This study presents a comprehensive carbon footprint (CF) assessment of the Universidad Cooperativa de Colombia’s (UCC) nine urban campuses, quantifying Scope 1, Scope 2, and selected Scope 3 emissions in accordance with the corporate accounting and reporting standard greenhouse gas (GHG) emissions protocol. Using a harmonized multi-campus framework for 2019–2022, the analysis reveals substantial variability in both total and per capita emissions between campuses located in hot–humid and hot–dry climatic zones, with heterogeneous trajectories relative to the 2019 baseline. Across the system, fugitive emissions primarily from refrigerants were the dominant source under Scope 1, followed by purchased electricity (Scope 2) and staff air travel (Scope 3). Despite differences in emission trends, a consistent decline in electricity consumption was observed. Documented efficiency measures including large-scale light-emitting diode (LED) retrofits, solar outdoor lighting, and operational controls to curb non-essential electricity use align temporally with observed demand reductions. The results underscore the importance of refrigerant management and targeted energy strategies in warm-climate higher education institutions. This study establishes a measurement, reporting, and verification compatible baseline for institutional decarbonization planning and highlights the need to progressively expand Scope 3 coverage to capture the full value chain footprint. }, doi = {10.61435/ijred.2026.62461}, url = {https://ijred.cbiore.id/index.php/ijred/article/view/62461} }
Refworks Citation Data :
This study presents a comprehensive carbon footprint (CF) assessment of the Universidad Cooperativa de Colombia’s (UCC) nine urban campuses, quantifying Scope 1, Scope 2, and selected Scope 3 emissions in accordance with the corporate accounting and reporting standard greenhouse gas (GHG) emissions protocol. Using a harmonized multi-campus framework for 2019–2022, the analysis reveals substantial variability in both total and per capita emissions between campuses located in hot–humid and hot–dry climatic zones, with heterogeneous trajectories relative to the 2019 baseline. Across the system, fugitive emissions primarily from refrigerants were the dominant source under Scope 1, followed by purchased electricity (Scope 2) and staff air travel (Scope 3). Despite differences in emission trends, a consistent decline in electricity consumption was observed. Documented efficiency measures including large-scale light-emitting diode (LED) retrofits, solar outdoor lighting, and operational controls to curb non-essential electricity use align temporally with observed demand reductions. The results underscore the importance of refrigerant management and targeted energy strategies in warm-climate higher education institutions. This study establishes a measurement, reporting, and verification compatible baseline for institutional decarbonization planning and highlights the need to progressively expand Scope 3 coverage to capture the full value chain footprint.
Article Metrics:
Last update:
Last update: 2026-11-23 16:33:58
This journal provides immediate open access to its content on the principle that making research freely available to the public supports a greater global exchange of knowledge. Articles are freely available to both subscribers and the wider public with permitted reuse.
All articles published Open Access will be immediately and permanently free for everyone to read and download. We are continuously working with our author communities to select the best choice of license options: Creative Commons Attribution-ShareAlike (CC BY-SA). Authors and readers can copy and redistribute the material in any medium or format, as well as remix, transform, and build upon the material for any purpose, even commercially, but they must give appropriate credit (cite to the article or content), provide a link to the license, and indicate if changes were made. If you remix, transform, or build upon the material, you must distribute your contributions under the same license as the original.
International Journal of Renewable Energy Development (ISSN:2252-4940) published by CBIORE is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.